Fire Trace Systems

Fire Trace Systems

Cease Fire & Electrical Services one of the reliable and trusted supplier and installation company of Fire Trace System or Fire Suppression System in Mumbai India.

Cease Fire & Electrical Cervices is approved & Certified by UL, CE, FM, ISO 9001.


Designed for simple installation, often very near the source of a potential fire, Fire trace system is a self-activating suppression system that reliably suppresses fires in seconds. Fire trace system is a low maintenance, cost-effective solution to the problem of "micro-environment" fire protection.

Micro-environments are applications where the hazard is typically contained within a critical enclosure, such as equipment, machines, vehicles, or storage compartments. Fire trace systems can be installed in virtually any enclosed space where high-value assets are located or where an increased risk of fire could be mitigated by an automatic fire suppression system.

Fire trace systems are compatible with most commercially available fire suppression agents, including "clean" extinguishing agents such as FM-200 or Novec 1230 fire protection fluid, as well as CO2, dry chemical powder, foam, and water.

Benefits of Fire Trace System

The faster extinguishing effect of Fire Trace System as compared with conventional Low Pressure (25 Bar) system is achieved solely by means of the high pressure (42 Bar) technology. Due to high pressure rapid and reliable extinguishing of fire is ensured.
  • Rapid release of Gas
  • Total vaporization already during flooding
  • Perfect homogenization before flooding is complete
  • Because of minimum operating pressure of 10 bar at nozzles, droplet size, arising from atomization of FM-200, are smaller resulting in complete vaporization before it can collide with any object. It also allows rooms to be flooded up to a height of five meters, a special advantage over conventional low-pressure systems, which are usually limited to room heights of less than four meters.
  • Maximum filling ration can be realized by comparison with conventional low pressure system and so optimizes the ratio of hardware required to each kilogram of FM-200.
  • Smaller diameter of piping network can be used thus reducing installation cost.
  • More than one room in a building can be protected by providing a common cylinder battery (Central Bank) and sector/directional valve. The capacity of the cylinder battery shall be calculated for the protection of the largest room and/or adjoining rooms, which may be evaluated to be involved in a fire simultaneously. Fire Trace System direction valve systems, in most cases reduce the cost involved compared to the cost for individual systems protecting the same hazards.

Design Standards of Fire Trace System
Fire Trace System system shall always be designed in accordance with the latest version of applicable international design standard. In most countries, the recommendations for industrial applications as laid down in the NFPA Standard 2001 are acceptable.

Clean Agent System
Cease Fire & Electrical Services specializes in the design, manufacture, installation and service of fixed fire fighting systems. Established internationally and with a pioneering record in fire engineering, Cease Fire & Electrical Services has conducted an extensive programme of product development and research to produce a superior gaseous system.

Fire Extinguishing Agent
In response to the impending production phase-out of Halon fire extinguish ants, Cease Fire & Electrical Services offers Fire Trace System as a replacement for Halon 1301 in applications requiring a clean, environmentally acceptable fire extinguishing agent, suitable for use in manned areas. It is a colorless gas at standard conditions, exhibiting a boiling point of -16.4°C. Through the use of properly designed equipment, FM-200 will mix well in a protected enclosure to provide a homogeneous mixture in air.

How Fire Trace System works
In order for a fire to be sustained, the three components fuel, oxygen and heat, must be present in sufficient quantities, and at sufficient levels. If one of the three elements is removed the fire will be suppressed. Fire Trace Systems works by physical action, the molecules absorb heat so that the temperature of the flame falls to a point below which it cannot propagate, and the fire is extinguished. The oxygen depleting effect is minimal as only small quantities of the gas are used.

Introducing the Fire Trace Engineered systems
The combination of extinguishant and advanced system components offered by us is considered to be the ultimate gaseous system for a multitude of applications. These systems are individually designed for each customer's requirement utilising an Approved Design Manual and Hydraulic Calculations Package.

  • Individually tailored to meet exact requirements
  • Efficient use of extinguishant
  • Cost-effective use of pipework, layout and materials
  • Effective protection

Extinguishing power

Rapid fire knockdown within ten seconds
The system will protect at low concentrations of extinguishant, between 7 and 9%, a design which ensures a rapid fire knockdown essential for personnel and property protection. This low concentration also means that over pressurization of rooms and enclosures is restricted, an important feature sometimes overlooked. These systems are equally suitable for flammable mixtures of fuel found in, for example, marine engine compartments or for electrically sensitive equipment in communication technology.

Personnel safety

Safe in manned areas
In determining a safe exposure level to any agent intended for use in occupied spaces, the potential of the agent to cause cardiac sensitization should be determined. Fire trace system has been evaluated for this condition via test protocols approved by the US Environmental Protection Agency, and has been cleared for use in occupied areas at the normal design concentration. Fire trace system has a low toxicity rating and is classified as: Safe for automatic operation in areas where staff are at work and that it has No observed adverse effect on humans at concentration of 9%(Systems are designed for lower concentrations than 9%) Additionally, because the system assures rapid knockdown, inhalation of fumes from the burning materials causing the fire are minimized and smoke build up restricted.

Environmentally safe

Ozone Depletion Potential (ODP)
As the concerns over stratospheric ozone protection have developed in recent years, it is clearly understood that any agent that is expected to be available for use in the market on a long term basis would have to offer zero ODP. In the past, certain gases such as Halon 1301 were utilised in systems until it was realised that they could deplete the ozone layer. Since Fire Trace System contains no chlorine or bromine and does not possess the properties associated with the compounds thought to damage stratospheric ozone it has an ozone depletion potential of zero.

Global Warming Potential

Biodegradability of chemical compounds in the environment is also a paramount concern. Long-lived compounds are thought to pose greater risks of contributing to global warming. Determination of the atmospheric lifetime of Fire Trace System, indicates a lifetime of only 31 to 42 years. This lifetime has been considered as acceptable for fire extinguishing compounds by the US Environmental Protection Agency's Significant New Applications Programme (SNAP).

Practical solution

Compact cylinder requirement
As the Fire Trace System is a liquefiable gas, a wide range of fill ratios are available which ensures a cost effective application of container and contents through accurate systems calculations. Our Fire Trace systems incorporate advanced design criteria to increase flow and installation efficiency by 100%, giving maximum flexibility to new and retrofit installations. Fire Trace System system cylinders offered are only pressurised at 25 bar and can be located within the risk area without a separate cylinder room enclosure.

Detection

Activation of the FM 200 fire system can be carried out electrically, pneumatically, or manually with either local or remote control. The system can be connected to existing detection control stations situated on site or be provided with a new detection system.

Design basis of Fire Trace System

  • Applicable Standard : NFPA 2001
  • Room temperature; considered : 21 Deg.C
  • Minimum conc. of agent as per (NFPA) 2001 : 7.0%
  • Max. Concentration of gas as per (NFPA) 2001 : 9.0%
  • Flooding Factor : 0.5483 Kg/m3
  • System pressure : 25 Bar
  • Min. pressure requirement at nozzle : Min. 6.034 Bar
  • Discharge time : 10 Sec. (Maximum)
  • Cylinder Size : 80 Litre
  • Minimum fill in cylinder : 38.5 Kg
  • Maximum fill in cylinder : 84.5 Kg
  • Nozzle coverage area 180 deg : 10.2M radius (maximum)

Returns Policy: Once goods sold will not be taken back.

For more information go through our website http://www.ceasefireservices.com or call / mail us.

We provide these Fire Trace System services all across India in cities like

Mumbai (Dadar, Bandra, Andheri, Borivilli, Palghar, Churchgate, Fort, Vasai, Sion, Chembur, Kalyan, kurla, Virar, Belapur, Ghatkopar), Navi Mumbai, Vashi, Thane, Shirdi, Vapi, Lonavala, Lavasa, Matheran, Mahabaleshwar, Nagpur, Aurangabad, Solapur, Kolhapur, Surat, Pune, Ahmedabad, Nashik, Ratnagiri, Bengaluru, Hyderabad, Baroda, Goa.