Fire Safety for Commercial Buildings and Offices in Mumbai

Cease Fire & Electrical Services LLP designs, installs and maintains fire protection for commercial buildings and offices in Mumbai: hydrants, sprinklers, addressable fire alarms, public address, gas suppression for server and electrical rooms, passive fire protection and continuous monitoring of the fire systems. As a Maharashtra Fire Services licensed agency since 1992, we issue Form A and Form B certificates, and we are licensed to carry out fire and life safety audits. Our clients include TCS, Honeywell, BSNL and MTNL.

What commercial buildings in Mumbai must comply with

  • Form A: a licensed agency certifies fire systems when they are installed or changed.
  • Form B: under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, owners and occupiers must submit a certificate from a licensed agency every January and July, confirming the systems are maintained and working.
  • Fire and life safety audit: required for certain buildings under the Act, carried out by a licensed auditor. We hold Fire and Life Safety Auditor licence MF&ES/F&LSA/30052026/011.
  • ACMS: the rules amended on 12 June 2025 added an Automated Continuous Monitoring System for covered buildings, with Form A-1 from the agency and Form B-1 from the owner twice a year.
  • Design standards: systems follow the National Building Code (NBC 2016) and the Act's minimum requirements. Tenants and insurers may also ask for NFPA or FM guidelines.

Fire protection for each part of a commercial building

  1. Office floors and lobbies

    Fire spreading through open floors and ceiling voids

    Sprinklers, addressable fire alarm, PA system, extinguishers, signage

  2. Risers, staircases and basements

    Firefighting water supply and safe escape

    Fire hydrant system, fire pumps, basement sprinklers

  3. Server rooms and UPS rooms

    Equipment damage from water

    Clean agent suppression (Novec 1230, Honeywell FK-5-1-12) or FM-200 (HFC-227ea)

  4. Electrical panels and LT rooms

    Electrical faults starting a fire

    Electrical panel protection, including tube suppression inside panels

  5. Cafeterias and food courts

    Cooking oil fires

    Kitchen wet chemical suppression (UL 300 listed Lehavot WCK, INTIME)

  6. Shafts, service openings and exits

    Smoke and fire passing between floors

    Passive fire protection: fire sealants and fire doors

  7. Pump room, tanks and alarm panels

    A system that fails without anyone knowing

    FireSense IoT monitoring with remote alerts

For large server rooms, see data centres and electrical rooms.

Fit-outs and occupied buildings

When an office is refitted, the fire systems must follow the new layout. We extend sprinklers, detectors and PA speakers to new partitions and ceilings, connect them to the building's main panel, and certify the work. We plan the work with building management so occupied floors stay protected.

Monitoring the building's fire systems

A fire system that has failed silently is the main risk in a managed building. Our FireSense IoT panel watches the fire alarm panel status, fire pumps, water tank levels, and hydrant and sprinkler line pressure, and sends alerts to your facility team. A cloud dashboard keeps live and historical data for reports and audits. This is the type of continuous monitoring the Maharashtra ACMS rules ask for. See Fire IoT Monitoring System and our ACMS Form A-1 and B-1 guide.

From installation to Form B

  1. Free site survey of your building or review of your drawings.

  2. Design of fire and MEP systems by our MEP design team.

  3. Installation, testing and commissioning, with Form A on completion.

  4. Maintenance under a commercial building AMC, with most systems checked quarterly and serviced annually.

  5. Form B every January and July, and a fire safety audit when you need one.

Why choose Cease Fire

  • Since 1992

    1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).

  • Licensed

    Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95), Fire and Life Safety Auditor, and Maharashtra Electrical Contractor Licence No. 17545. See our certifications.

  • Beyond fire

    Electrical audits and energy audits by BEE-certified energy auditors.

  • Own monitoring product

    FireSense IoT, installed and supported by the same team.

  • Coverage

    Mumbai, Thane, Navi Mumbai, Maharashtra and projects across India.

Book a free site survey

Tell us about your building: location, floors, use and the systems you have now. We'll inspect it and recommend what it needs.

Frequently asked questions

What fire safety systems does a commercial building need in Mumbai?

It depends on the building's height, floor area and use, under the NBC and the Maharashtra Fire Act. Most office buildings need extinguishers, hose reels and hydrants, sprinklers, fire detection and alarm, a PA system, signage and fire exits. We confirm the list after a site survey.

What is Form B and when is it due?

Form B is a certificate from a licensed agency confirming that a building's fire systems are maintained and working. Under the Maharashtra Fire Act, it must be submitted every January and July.

What is the difference between Form A and Form B?

Form A is issued by the licensed agency when fire systems are installed or changed. Form B is the six-monthly certificate that they are still maintained and working.

What is ACMS and does my office building need it?

ACMS is the Automated Continuous Monitoring System introduced by the Maharashtra fire rules amended on 12 June 2025, for covered buildings. A licensed agency certifies it on Form A-1, and the owner files Form B-1 in January and July. Ask your fire officer whether your building is covered, and we can supply and certify the monitoring.

Who is responsible for fire safety in an office building, the owner or the tenant?

The Act places the duty on both owners and occupiers. Usually the building owner maintains the main systems, and each tenant maintains the systems inside its own premises. Check your lease for the exact split.

How should a server room in an office be protected?

Server rooms are usually protected with a clean agent gas system such as Novec 1230 or FM-200. It puts out the fire without water, so equipment is not damaged.

Do commercial buildings need a fire audit?

The Maharashtra Fire Act requires fire and life safety audits for certain buildings. Insurers and tenants often ask for one too. We are a licensed Fire and Life Safety Auditor.

Can you work in an occupied office building?

Yes. We plan the work with building management so that occupied floors stay protected during installation and upgrades.

How do I book a site survey?

Call +91 9920676281, email sales@ceasefireservices.com, or use the enquiry form. The site survey is free.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.