Fire Hydrant System Installation in Mumbai
Cease Fire & Electrical Services LLP provides fire hydrant system installation in Mumbai, from design and the pump room to wet risers, hose reels, yard hydrants and the fire brigade inlet. We are a Maharashtra Fire Services Licensed Agency and have delivered fire protection projects for housing societies, commercial buildings, factories and government sites since 1992. After testing, we issue Form A and can maintain the system under AMC.
What is a fire hydrant system?
A fire hydrant system is a network of fixed pipes kept full of water under pressure by dedicated fire pumps, with outlets where hoses are connected to fight a fire. Inside a building, the vertical pipe is called a wet riser, with a landing valve, hose box and hose reel on each floor. Outside, yard hydrants sit on a ring main around the buildings. The system gives trained staff and the fire brigade a reliable water supply from the first minutes of a fire.
Where hydrant systems are needed

Residential towers and housing societies
Wet riser with landing valves, hose boxes and hose reels on each floor, terrace booster pump, fire brigade inlet

Commercial buildings and offices
Wet riser and hose reels, pump room shared with the sprinkler system

Factories and warehouses
Yard hydrant ring main around the buildings, internal hydrants and hose reels, pump room sized for the site

Hospitals, hotels and schools
Wet riser and hose reels on every floor, linked to sprinklers and fire alarms

Government and institutional campuses
Complete fire fighting systems for hostels, offices and public buildings
The systems a building needs depend on its height, use and floor area under the National Building Code of India (NBC) and the fire brigade's requirements. We confirm this during the free site survey.
Components of a fire hydrant system

Fire water tank
Stores water kept only for firefighting

Main hydrant pump (electric)
Delivers water at the design pressure and flow

Diesel engine pump
Standby pump that runs if mains power fails

Jockey pump
Keeps the pipes pressurised and makes up small leaks, so the main pump does not start unnecessarily

Terrace booster pump
Supplies the upper floors of tall buildings

Pump control panel and pressure gauges
Start the pumps automatically when pressure drops and show system pressure

Wet riser with single or double outlet hydrant valves
Gives an outlet for fire hoses on every floor

Hose box with canvas hoses, couplings and branch pipe
Keeps hoses ready next to each hydrant valve

Hose reel drum with rubber hose and shut-off nozzle
Lets trained occupants tackle a small fire early

Yard hydrant valves
External outlets on the ring main around the site

Fire brigade inlet
Lets the fire brigade pump water into the system from its tender

Isolation and non-return valves
Isolate sections for repair and keep water flowing the right way
We supply the hydrant valves, hoses, hose reels, hose boxes, fire pumps and valves ourselves. UL listed and FM approved pumps and valves are available where your consultant or insurer needs them.
Design standards
We design hydrant systems to the NBC and NFPA standards, and to UL/FM requirements where the project calls for them. Our MEP engineers prepare the layout and drawings, and we check pipe sizes and pump duty with hydraulic calculations before anything is installed.
Hydrant valves, hose, couplings and branch pipes we supply are made to Indian Standards: IS 5290 (Type A and Type B landing valves), IS 636 (RRL hose), IS 903 (couplings and branch pipes) and IS 884 (hose reels), from SANT and other makers.
Our process
Free site survey
We visit the site, study the building and any existing system, and confirm what the fire brigade will expect.
Design
Layout, pump sizing, hydraulic calculations and drawings.
Supply and installation
Pump room, pipework, risers, valves, hose boxes and hose reels, installed by our own team.
Testing and commissioning
Pressure testing of the pipework, pump performance and flow at the outlets, and a demonstration and training for your staff.
Form A
As a licensed agency, we issue the Form A certificate for the work we have done, which you submit to the fire brigade.
AMC and Form B
Planned maintenance, usually quarterly checks with an annual service, and the Form B certificate each January and July.
Continuous monitoring of the hydrant system
In Maharashtra, covered buildings must now have an Automated Continuous Monitoring System (ACMS) under the fire rules amendment of 12 June 2025. We connect the hydrant pump room to our FireSense IoT panel, which reports the status of the main, jockey and diesel pumps, the diesel tank level, pump power and the fire water tank every minute. The owner and the licensed agency are alerted when something fails, so a flat battery or a stopped jockey pump is found before it matters. Read our guide to ACMS, Form A-1 and Form B-1, or see FireSense IoT monitoring.
Hydrant projects

LBS IMU Mumbai Port Campus (CPWD), Sewri
Fire fighting and sprinkler systems for a G + 11 hostel.

Palkhi Roha, Kandivali East (G + 14)
Fire fighting, sprinkler, fire detection and signage systems, completed in April 2024.

Palkhi MRDA, Kandivali (G + podium + 13), for KCD Realty
Fire fighting, sprinkler, fire detection and signage systems.
Maintenance and Form B
A hydrant system only works if it is maintained. On each service visit we check the main, jockey, diesel and booster pumps, the pump control panel and pressure gauges, every hydrant valve, coupling, hose, hose reel, nozzle, hose box and branch pipe, the yard hydrants and the fire brigade inlet. Under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, building owners must submit a Form B certificate from a licensed agency every January and July. We can include it in your AMC.
Why choose Cease Fire
Since 1992
1,500+ projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ), so we issue Form A and Form B ourselves.RF-93/ RD-95 Design in-house
Our MEP team designs the system and runs the hydraulic calculations.
One team
Pump room, pipework, products, testing and AMC from one company.
Government work
CPWD enlisted, with projects such as the LBS IMU hostel in Sewri.
Book a free site survey
We work across Mumbai, Thane, Navi Mumbai and Maharashtra, and take on projects across India. Tell us your building type, number of floors and location, and send drawings if you have them. We will visit, confirm what the fire brigade needs and send a clear proposal.
Frequently asked questions
What is a fire hydrant system?
A fire hydrant system is a network of pipes kept full of water under pressure by fire pumps, with hydrant valves where fire hoses are connected. It gives a reliable water supply for fighting a fire inside and around a building.
What are the main parts of a fire hydrant system?
The main parts are the fire water tank, the main, jockey and diesel fire pumps, the pump control panel, the wet riser or ring main, hydrant valves, hoses, hose reels, hose boxes and the fire brigade inlet.
What is the difference between a wet riser and a yard hydrant?
A wet riser is a vertical pipe inside a building with a hydrant valve on each floor. Yard hydrants are outlets on a pipe ring main laid around the outside of the buildings, common in factories and large campuses.
Which buildings need a fire hydrant system?
It depends on the building's height, use and floor area under the National Building Code and the fire brigade's requirements. We confirm exactly what your building needs during a free site survey.
Does Cease Fire provide Form A after installing a hydrant system?
Yes. As a Maharashtra Fire Services Licensed Agency, we issue Form A for the work we complete, which you submit to the fire brigade.
How often should a fire hydrant system be serviced?
Most sites have quarterly checks and an annual service under AMC. A licensed agency must also inspect the system and issue Form B every January and July.
Can you upgrade or repair an existing hydrant system?
Yes. We review the existing system, list what needs rectifying or replacing, and carry out the work with the right documentation.
How much does a fire hydrant system cost?
The cost depends on the building size, pump capacity, length of pipework and number of outlets. We give a written quote after a free site survey or from your drawings.
Can a hydrant system be monitored remotely?
Yes. Our FireSense IoT panel reports pump status, diesel tank level, pump power and tank levels, and supports the ACMS now required for covered buildings in Maharashtra. Alerts go to the owner and to us as the licensed agency.