Fire Alarm System Installation in Mumbai

Cease Fire & Electrical Services LLP provides fire alarm system installation in Mumbai: conventional, addressable and wireless fire detection and alarm systems designed to IS 2189 and NFPA 72. We supply, install, test and maintain the panel, detectors, call points and sounders for offices, housing societies, factories, hospitals and utility sites. Our recent work includes addressable fire alarm systems at 65 Adani Electricity receiving substations across Mumbai.

How a fire alarm system works

Detectors watch for smoke or heat in every area, and manual call points let anyone raise the alarm by hand. When a device operates, the fire alarm panel sounds the hooters and strobes, shows where the fire is, and can signal other systems, such as the public address system, sprinkler flow switches or a gas suppression panel. The earlier a fire is detected, the more time people have to leave safely.

Types of fire alarm systems we install

  1. Conventional

    Devices are wired in zones; the panel shows which zone is in alarm

    Smaller buildings, shops and small offices

  2. Semi-addressable

    Addressed devices plus conventional zones on one system; the panel shows the device for addressed parts and the zone for the rest

    Mid-sized buildings that need more detail than zones alone

  3. Addressable

    Every device has its own address, so the panel shows the exact detector or call point

    Large buildings, campuses, hospitals and industrial sites

  4. Wireless

    Detectors and sounders communicate by radio with the panel

    Heritage buildings, occupied offices and sites where new cabling is difficult

We also install public address (PA) systems for voice announcements and evacuation messages.

Components of a fire alarm system

We supply all of these devices, from panels to detectors and PA equipment.

Design standards

We design fire detection and alarm systems to IS 2189 and NFPA 72, and to FM guidelines where the insurer requires them, as on our Roquette India project. Detector type and spacing are chosen for each room's height, use and airflow, and the cabling is laid out so the system can be extended later.

Our process

  1. Free site survey

    We review the building, room uses and any existing system.

  2. Design

    System type, device layout, zoning or loop design and cable routes.

  3. Supply and installation

    Panel, detectors, call points, sounders and cabling, installed by our own team.

  4. Testing and commissioning

    Every device tested, panel programmed, links to other systems checked, and staff trained.

  5. Form A

    As a licensed agency, we issue Form A for the work, which you submit to the fire brigade.

  6. AMC and Form B

    Usually quarterly checks with an annual service, and Form B every January and July.

Fire alarm monitoring under ACMS

The Maharashtra ACMS rules of 12 June 2025 require the fire alarm panel to be monitored continuously in covered buildings. FireSense IoT reports the panel and repeater status, battery condition, detection faults and manual call point operation, and also the PA system, so a dead battery or a faulty loop is flagged at once. The owner and the licensed agency receive the alert. See our ACMS guide or FireSense IoT monitoring.

Fire alarm projects

  • Engineer in a hard hat testing an open red fire alarm control panel with a handheld meter, a call point on the wall beside it

    Adani Electricity Mumbai

    Supply, installation, testing and commissioning of addressable fire alarm systems at 65 receiving substations across Mumbai, May 2024 to January 2026, completed within the contract period.

  • Engineer on a scissor lift tightening the clamp of a sway brace on a red sprinkler main under a warehouse roof

    Roquette India, Pantnagar

    Fire alarm systems to FM guidelines, with roof sprinklers and seismic bracing, for four godowns.

  • Engineer in a hard hat drawing the nozzle from a red hose reel in an open wall cabinet

    Palkhi Roha, Kandivali East (G + 14)

    Fire detection with fire fighting, sprinklers and signage, completed in April 2024.

  • Engineer reading the pressure gauge on a red riser valve above a four-way fire brigade inlet, at the entrance of a residential tower with a slatted, planted podium

    Palkhi MRDA, Kandivali (G + podium + 13), for KCD Realty

    The same complete package.

See all projects and case studies

Maintenance and Form B

Detectors collect dust, batteries age and devices get covered or damaged during fit-outs. Under AMC we test the panel, detectors, call points and sounders, check the standby batteries, and record and rectify faults. A licensed agency must inspect the fire systems and issue Form B every January and July, and we can include this in your AMC.

Why choose Cease Fire

  • Since 1992

    1,500+ projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).

  • Fire and electrical licences

    Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95) and Maharashtra Electrical Contractor Licence No. 17545.

  • Large-scale delivery

    Addressable fire alarms at 65 Adani Electricity substations.

  • Every system type

    Conventional, semi-addressable, addressable, wireless and PA.

  • One team

    Design, devices, installation, testing and AMC from one company.

Book a free site survey

Tell us your building type, floor area and location, and send drawings if you have them. We will recommend the right system and send a clear proposal.

Frequently asked questions

What is the difference between a conventional and an addressable fire alarm system?

A conventional system groups devices into zones, so the panel shows only which zone is in alarm. An addressable system gives every device its own address, so the panel shows the exact detector or call point that operated.

Which fire alarm system is right for my building?

Conventional systems suit smaller buildings, while addressable systems suit large buildings and sites where finding the exact device quickly matters. We recommend the right type after a free site survey.

Do you install wireless fire alarm systems?

Yes. Wireless systems suit buildings where running new cables is difficult or disruptive.

What standards do you follow for fire alarm systems?

We design fire detection and alarm systems to IS 2189 and NFPA 72, and to FM guidelines where the insurer requires them.

Can the fire alarm be connected to sprinklers and a PA system?

Yes. Sprinkler flow switches connect to the panel through control modules, and the panel can trigger the public address system for evacuation announcements.

How often should a fire alarm system be tested?

Most sites have quarterly checks and an annual service under AMC, plus the Form B inspection by a licensed agency every January and July.

Why does my fire alarm keep giving false alarms?

Common causes are dusty or dirty detectors, the wrong detector type for the area, such as smoke detectors in kitchens, and wiring faults. A service visit finds and fixes the cause.

Can the fire alarm panel be monitored remotely?

Yes. FireSense IoT monitoring reports panel, repeater, battery, detector and call point status, which supports the ACMS required for covered buildings in Maharashtra.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.