Fire Alarm Panel in Mumbai

A grey fire alarm control panel with a small display, rows of indicator lamps and a key switch, fixed to a concrete wall

Cease Fire & Electrical Services LLP supplies, installs and programs the fire alarm panel for buildings in Mumbai, including housing societies, offices, hospitals, hotels, schools, factories and warehouses. The fire alarm panel is the control unit of the system: it powers the detectors, call points and hooters, raises the alarm when any of them operates, shows where the fire is and reports faults. We supply conventional and addressable panels sized to your building and commission each one before handover.

Conventional or addressable panel

  1. How devices connect

    On zone circuits

    On loops, each device with its own address

  2. Panel size

    Given by the number of zones

    Given by the number of loops

  3. What the panel shows

    The zone in alarm

    The exact device in alarm

  4. Limit in IS 2189:2008

    Up to 20 conventional detectors per zone

    Up to 8 fire zones per loop, at least two isolators per zone

  5. Suits

    Smaller buildings with few zones

    Larger or taller buildings, and buildings with many services to control

A semi-addressable panel sits between the two, with conventional detectors grouped behind zone modules on an addressable loop.

What the panel does

  • Powers the detectors, call points and sounder circuits, with a standby battery for power cuts
  • Raises the alarm and switches on hooters and strobes
  • Shows the zone or device in alarm, and any wiring or power fault
  • Runs the building's cause and effect plan through control modules, such as AHU shutdown and lift recall
  • Keeps an event log of alarms, faults and tests

Where the panel goes

IS 2189:2008 asks for a control centre, preferably on the ground floor, where the panel, any mimic panel and the control equipment are installed. Where needed, a repeater or annunciator panel should be fitted near the main entrance so staff and fire brigade crews can see the alarm and any fault or isolation.

Standards to know: EN 54-2 covers fire alarm control and indicating equipment, EN 54-4 covers their power supplies, and UL 864 is the US standard for fire alarm control units.

What to tell us

Building
Floors, floor area and use
Devices
Number of detectors, call points and sounders, or your BOQ
Services to control
AHUs, lifts, fans, doors, PA system
Existing system
Panel make and model and device make, if replacing or upgrading

Supply, installation and servicing

We supply panels sized to your devices, install them in the control room, connect the loops or zones and batteries, program the zones or device labels and the cause and effect plan, and test every input and output before handover. Under our AMC, the panel, batteries and event log are checked during quarterly visits and the annual service.

For covered buildings in Maharashtra, the Automated Continuous Monitoring System (ACMS) rules of 12 June 2025 require the panel, repeater, battery, detection and call point status to be monitored continuously. Our FireSense IoT panel reads these and alerts the owner and the licensed agency. See the ACMS guide.

Engineer testing a wall-mounted fire alarm control panel, with a manual call point and a smoke detector nearby

Why choose Cease Fire

  • Since 1992

    A Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95) that designs, installs and maintains fire alarm systems.

  • Proven on addressable work

    Addressable fire alarm systems at 65 Adani Electricity substations in Mumbai.

  • Fire and electrical in one team

    A Maharashtra Electrical Contractor (Licence No. 17545), so the mains supply and links to other building services are handled by our own licensed team.

Request a quote

Send your device list or BOQ, the number of floors, and your current panel make and model if you are replacing one. We will confirm the right panel and send a quote.

Frequently asked questions

What is a fire alarm panel?

It is the control unit of a fire alarm system. It powers the devices, raises the alarm when a detector or call point operates, and shows where the fire is.

Which is better, a conventional or an addressable fire alarm panel?

A conventional panel suits smaller buildings with a few zones. An addressable panel shows the exact device in alarm and suits larger or taller buildings and those with many services to control.

How many zones or loops do I need?

IS 2189 allows up to 20 conventional detectors per zone and up to 8 fire zones per addressable loop. We work out the panel size from your device list or layout.

Where should the fire alarm panel be installed?

IS 2189 asks for a control centre, preferably on the ground floor. A repeater panel near the main entrance helps staff and the fire brigade see the alarm quickly.

Can I replace my old fire alarm panel without changing the detectors?

Sometimes, if the new panel works with the existing devices, which is common on conventional systems. Addressable devices usually need a panel of the same make and protocol, so share your current panel and device models first.

Why does my fire alarm panel show a fault?

Common causes are a wiring break or short, a removed detector, a low or failed standby battery, or a mains supply problem. The panel shows the fault type and location, and our team can trace and fix it.

Can the fire alarm panel be monitored remotely for ACMS?

Yes. FireSense IoT monitoring reports panel, repeater, battery, detection and call point status every minute, which supports the ACMS required for covered buildings in Maharashtra.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281