Cease Fire & Electrical Services LLP supplies, installs and maintains the fire alarm isolator module for addressable fire alarm systems in Mumbai, for commercial towers, hospitals, hotels, factories and high-rise housing societies. An isolator module cuts off the short section of an addressable loop when a cable is shorted, so the rest of the loop keeps detecting fires and the panel shows where the fault is. We supply isolators to match your panel and place them at each zone boundary before handover.

How an isolator module works

An addressable loop starts and ends at the panel, so every device can be reached from both directions. When a short circuit happens, the isolators on either side of it open and cut off only that section. The panel feeds the rest of the loop from both ends, keeps every other device working and reports a fault. Once the cable is repaired, the isolators close again. Without isolators, one damaged cable can take down every detector and call point on the loop.

Isolator module
A separate module fitted in the loop, usually at a zone or floor boundary
Isolator base
A detector base with a built-in isolator
Built-in isolator
Some addressable devices have an isolator inside the device itself

How many isolators you need

Loop wiring
Class A, returning to the panel
Fire zones per loop
No more than 8
Isolators per zone
At least two
Recommended spacing
A pair of isolators for every 20 to 30 detectors or call points
Loop length
Up to 3,000 m with cable of at least 1.5 mm², or as the maker recommends
Devices per loop
Up to 90% of the loop's full capacity

Isolators are also counted as loop devices, so they reduce the number of detectors a loop can take.

Supply, installation and servicing

We supply isolators to match your panel's make and protocol, fit them at zone boundaries, and test the loop by simulating a short to confirm only that section drops out. Under our AMC, loop faults and isolator status are checked during quarterly visits and the annual service.

Loop faults and panel status can also be reported remotely through FireSense IoT monitoring, which supports the ACMS now required for covered buildings in Maharashtra.

Engineer testing a wall-mounted fire alarm control panel, with a manual call point and a smoke detector nearby

Why choose Cease Fire

  • Since 1992

    A Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95) that designs, installs and maintains fire alarm systems.

  • Proven on addressable work

    Addressable fire alarm systems at 65 Adani Electricity substations in Mumbai.

  • Right part first time

    We confirm panel compatibility and loop capacity before you order.

Request a quote

Tell us the panel make and model, the number of loops and zones, and the number of devices on each loop. We will confirm the isolators needed and send a quote.

Frequently asked questions

What is an isolator module in a fire alarm system?

It is a device on an addressable loop that cuts off a shorted section of cable. The rest of the loop keeps working and the panel shows a fault.

How many isolator modules do I need?

IS 2189 asks for at least two isolators per zone and recommends a pair for every 20 to 30 detectors or call points. A loop should carry no more than 8 fire zones.

Where should isolator modules be placed?

At the boundaries between zones or floors, and where the loop leaves and returns to the panel. That way a short on one floor cannot stop devices on another.

What is the difference between an isolator module and an isolator base?

An isolator module is a separate device in the loop. An isolator base is a detector base with the isolator built in, which saves a separate box.

Why does my addressable panel show a loop short circuit fault?

A cable may be damaged, pinched or wet, or a device may have failed. The isolators limit the damage, and the panel usually shows which section is affected so the fault can be traced.

Does an isolator module work with any fire alarm panel?

No, it must match the panel's make and protocol. Share the panel make and model and we will confirm a compatible isolator.

Can loop faults be reported remotely?

Yes. FireSense IoT monitoring reports fire alarm panel and detection faults to the owner and to us, which supports the ACMS required for covered buildings in Maharashtra.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.