Fire Sprinklers and Accessories in Mumbai

Cease Fire & Electrical Services LLP supplies fire sprinklers and sprinkler accessories in Mumbai: pendent, upright, sidewall and ESFR sprinkler heads, alarm and deluge valves, water curtain nozzles, flow switches, annunciator panels and flexible sprinkler hoses. Because we design and install sprinkler systems ourselves, we match each head and valve to the hazard, ceiling and layout it protects.
Sprinkler heads we supply

Pendent sprinkler
Hangs down from the pipe, usually through a false ceiling
Where it is usedOffices, flats, hotels, hospitals and shops

Upright sprinkler
Points up from exposed pipework
Where it is usedCar parks, plant rooms, stores and factories without ceilings

Sidewall sprinkler
Fixed on a wall, spraying outwards
Where it is usedCorridors, rooms and lobbies where ceiling piping is not practical

ESFR sprinkler
Large-orifice, fast-response head at roof level
Where it is usedWarehouses with high-piled or rack storage

Water curtain nozzle
Open nozzle that forms a sheet of water
Where it is usedOpenings, escalator voids and building faces in drencher systems
Each head is chosen by its temperature rating, K-factor (flow), response type and finish. See drencher system for water curtains.
Sprinkler valves and accessories

Sprinkler alarm valve
The main control valve of a wet sprinkler system. When a head opens, it lets water through and sounds the alarm.

Deluge valve
Releases water to all open nozzles at once when the detection system signals a fire. Used for drencher and water spray systems.

Flow switch (vane and normal type)
Detects water flowing in a floor or zone and signals the fire alarm panel.

Flow switch control module
Connects a flow switch to an addressable fire alarm system.

Sprinkler annunciator panel
Shows which floor or zone has water flow, so staff know where to go.

Flexible sprinkler hose (braided and unbraided)
Connects the branch pipe to a head in a false ceiling, making it quicker to fit and adjust the height.
Heads and valves chosen by the system designer
Sprinkler hardware only works as intended when it matches the design. Our engineers select heads, spacing and valves as part of sprinkler system design and installation, check pipe sizes with hydraulic calculations, and add seismic bracing where required.
Monitoring the sprinkler system
Flow switches tell the fire alarm panel which zone has water flow. For continuous monitoring of the water supply, our FireSense IoT panel tracks sprinkler and drencher line pressure, tank levels and pump status, and sends an SMS if data stops for 15 minutes. This supports the Automated Continuous Monitoring System (ACMS) required for covered buildings in Maharashtra since 12 June 2025.
Sprinklers on our projects

Roquette India, Pantnagar
Roof sprinklers, seismic bracing and fire alarm, to FM guidelines, in 4 godowns (January 2023 to February 2024).

LBS IMU Mumbai Port Campus (CPWD), Sewri
Fire fighting and sprinkler systems for a G + 11 hostel.

Palkhi Roha, Kandivali East (G + 14)
Fire fighting, sprinkler, fire detection and signage systems.

Palkhi MRDA, Kandivali (G + podium + 13)
Fire fighting, sprinkler, fire detection and signage systems.
See our projects.
See all projects and case studiesReplacement and servicing
Painted, damaged or corroded heads must be replaced with heads of the same type, temperature rating and K-factor. Our service visits check sprinkler alarm valves, sprinkler heads and flow switches, and our AMC covers the whole system with quarterly checks and an annual service for most sites.
Why choose Cease Fire
Since 1992
1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ). We issue Form B certificates. See our certifications.RF-93/ RD-95 Design experience
Sprinkler work to NFPA, NBC and FM guidelines, including warehouse roof sprinklers with seismic bracing.
One supplier
Sprinklers, valves, fire pumps and installation from one team.
Request a sprinkler quote
Send your BOQ, drawings or a list of heads and valves, with the building type and location. We will confirm the specification and quote.
Frequently asked questions
What is the difference between pendent, upright and sidewall sprinklers?
A pendent sprinkler hangs down from the pipe, usually below a false ceiling. An upright sprinkler points up from exposed pipes. A sidewall sprinkler is fixed on a wall and sprays outwards into the room.
What is an ESFR sprinkler?
ESFR stands for early suppression, fast response. These heads discharge a large volume of water quickly to suppress fires in high-piled and rack storage, and are mainly used in warehouses.
What do the colours of sprinkler bulbs mean?
The colour shows the temperature at which the bulb breaks. For example, orange is 57 °C, red 68 °C, yellow 79 °C and green 93 °C. We choose the rating to suit the normal temperature of each area.
What is the difference between an alarm valve and a deluge valve?
An alarm valve is the main control valve of a wet system: when a closed head opens, water flows through it and it raises an alarm. A deluge valve serves open nozzles and releases water to all of them at once when a detection system triggers it.
What does a flow switch do in a sprinkler system?
It senses water flowing in a pipe when a sprinkler opens, and sends a signal to the fire alarm panel showing which floor or zone is affected.
What is a water curtain nozzle used for?
It is an open nozzle that forms a sheet of water, used in drencher systems to protect openings, escalator voids and building faces. It works with a deluge valve and a detection system.
Can sprinkler line pressure be monitored for ACMS?
Yes. Our FireSense IoT panel monitors hydrant, sprinkler and drencher line pressure along with pumps and tanks. ACMS has applied to covered buildings in Maharashtra since 12 June 2025.
Can I replace a sprinkler head with a different type?
Only if it matches the original in K-factor, temperature rating, response type and orientation, as the system was designed around them. Our engineers check this before replacing any head.
Can you supply UL listed or FM approved sprinklers?
Yes. UL listed and FM approved sprinklers and valves are available. Tell us what your consultant or insurer specifies, and we will share the manufacturer's certificate for each model with our quote.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281