Fire Hydrant Accessories in Mumbai

Cease Fire & Electrical Services LLP supplies fire hydrant accessories in Mumbai: landing (hydrant) valves, RRL hose pipes with couplings, hose reel drums, hose boxes, branch pipes, fire brigade inlets and fire shaft doors. Our range includes ISI-marked stainless steel hydrant valves and RRL hoses. As a licensed fire services agency since 1992, we also install, test and maintain the hydrant systems these parts belong to.
Hydrant accessories we supply

Hydrant valve, single outlet
63 mm stainless steel (SS 304) oblique valve, 75 mm flanged inlet, 63 mm instantaneous outlet; 900 LPM flow test at 7 kg/cm². Also 80 mm bronze landing valves.
StandardIS 5290 Type A, ISI-marked

Hydrant valve, double outlet
63 mm stainless steel valve, 100 mm flanged inlet; 1,800 LPM flow test at 7 kg/cm²
StandardIS 5290 Type B, ISI-marked

RRL hose pipe
63 mm non-percolating RRL Type A hose in 7.5, 15, 22.5 and 30 m lengths, with stainless steel male and female instantaneous couplings
StandardHose IS 636 Type A; couplings IS 903, ISI-marked
Branch pipe with nozzle
Stainless steel short branch pipe, 63 mm inlet, 20 mm solid jet nozzle
StandardIS 903, ISI-marked

Hose reel drum
19 mm × 30 m and 25 mm × 30 m, swinging or fixed wall-mounted, with stainless steel shut-off nozzle. Tested for a 6 m horizontal throw at 7 kg/cm² with 40 LPM.
StandardDrum IS 884; hose IS 12585 Type 2, ISI-marked

Hose box
Single and double door MS hose boxes for hoses and branch pipes
Standard—
Fire brigade inlet
2-way (100 NB outlet) and 4-way (150 NB outlet), 63 mm inlets with non-return valves
Standard—

Fire shaft doors
Access doors for fire service shafts
Standard—
Hydrant valves and hoses are rated for working pressures up to 10 kg/cm², and hose reels up to 7 kg/cm².
Where each accessory fits in a hydrant system
See the fire hydrant system and fixed hydrant system pages for design and installation.
- Landing valves and hose boxes sit at each floor on the wet riser, or on yard hydrant posts around the site. Trained staff or the fire brigade connect the RRL hose and branch pipe to fight a fire.
- Hose reels are for first response by occupants. They give a smaller, easy-to-handle jet close to stairs and exits.
- Fire brigade inlets at ground level let fire tenders pump water into the system from outside.
- Fire shaft doors close the service shafts that carry the fire risers.
Choosing the right accessories
- Stainless steel valves resist corrosion and have a low scrap value, which reduces theft from open yards and common areas.
- Single or double outlet: a double outlet valve supplies two hose lines at once, where the design calls for more flow at one point.
- ISI-marked parts: fire authorities and auditors check that valves, hoses and hose reels meet the Indian Standards listed above.
- Matching couplings: all 63 mm instantaneous couplings must fit the fire brigade's hoses and each other. We check this before supply.
Replacement and servicing
Missing hoses, jammed valves and damaged nozzles are common findings in a fire safety audit. Our service visits check landing and yard hydrant valves, couplings and lugs, hose reel drums, hoses, shut-off nozzles, branch pipes, hose boxes and fire brigade inlets. We replace faulty parts, and include hydrant accessories in our AMC.
On our projects

Palkhi Roha, Kandivali East (G + 14)
Fire fighting, sprinkler, fire detection and signage systems.

Palkhi MRDA, Kandivali (G + podium + 13)
Fire fighting, sprinkler, fire detection and signage systems.

LBS IMU Mumbai Port Campus (CPWD), Sewri
Fire fighting and sprinkler systems for a G + 11 hostel.
Hydrant accessories are part of the fire fighting systems we install, including: See our projects.
See all projects and case studiesWhy choose Cease Fire
Since 1992
1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ). We issue Form B certificates. See our certifications.RF-93/ RD-95 One supplier
Hydrant accessories, fire pumps, valves and installation from one team.
Free site survey across Mumbai, Thane, Navi Mumbai and Maharashtra.
Request a quote
Send your BOQ or a list of the accessories you need, with the building location. We will confirm the specification and send a quote.
Frequently asked questions
What are fire hydrant accessories?
They are the parts that let people draw water from a hydrant system: landing valves, hoses, couplings, branch pipes and nozzles, hose reels, hose boxes and fire brigade inlets.
What is the difference between a single and a double outlet hydrant valve?
A single outlet valve (IS 5290 Type A) feeds one hose. A double outlet valve (Type B) feeds two hoses from a larger inlet. In our range, they are flow-tested at 900 LPM and 1,800 LPM at 7 kg/cm².
What is an RRL hose pipe?
RRL stands for reinforced rubber lined. It is the 63 mm delivery hose used with hydrant valves, made to IS 636 Type A, fitted with instantaneous couplings and supplied in standard lengths of 7.5, 15, 22.5 and 30 m.
What is the difference between a hose reel and a hydrant hose?
A hose reel uses a 19 mm or 25 mm hose on a drum and is meant for occupants to tackle a small fire early. A hydrant hose is 63 mm, delivers far more water and is used by trained staff or the fire brigade.
What is a branch pipe with nozzle?
It is the metal pipe fitted at the end of a hydrant hose to direct the water. Our short branch pipe has a 63 mm instantaneous inlet and a 20 mm solid jet nozzle, made to IS 903.
What is a fire brigade inlet?
It is a connection at ground level with 2 or 4 inlets. Fire tenders use it to pump water into the building's hydrant or sprinkler system.
Are stainless steel hydrant valves better than gunmetal ones?
Stainless steel resists corrosion and has a low scrap value, which reduces theft. We supply stainless steel hydrant valves and bronze landing valves, and can advise which suits your site.
Which Indian Standards apply to hydrant accessories?
IS 5290 covers landing valves, IS 636 fire hoses, IS 903 couplings and branch pipes, and IS 884 hose reels. Our valves, hoses, couplings and hose reel tubing are ISI-marked.
How do I get a quote, and do you install and replace parts?
Send your BOQ or a list of items to sales@ceasefireservices.com, call +91 9920676281, or use the enquiry form. We supply and install parts in new systems, and replace missing or damaged parts in existing buildings.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281