Addressable Monitor Module in Mumbai

Two small white fire alarm monitor modules wired with red cable on a piece of cable tray

Cease Fire & Electrical Services LLP supplies, installs and programs the addressable monitor module for fire alarm systems in Mumbai, for commercial towers, hospitals, hotels, factories, warehouses and high-rise housing societies. A monitor module gives a switch or signal that is not addressable its own address on the fire alarm loop, so the panel shows exactly which device has operated. It is used for flow switches, valve tamper switches, pump running and fault signals, suppression system signals and conventional call points.

What a monitor module connects

Sprinkler flow switch
Water flowing in a sprinkler zone
Valve tamper switch
A sprinkler or hydrant valve has been closed
Fire pump running or fault signal
Pump status in the pump room
Gas suppression system signal
Discharge or fault in a server or panel room
Conventional manual call point
The call point that was used, by address
Pressure switch or level switch
Low pressure or low tank level

The monitor module watches the wiring to the switch as well, so a cut or shorted cable shows as a fault on the panel.

Monitor module or control module

  1. Direction

    Input: brings a signal into the panel

    Output: sends a signal out from the panel

  2. Connected to

    Switches and contacts on other equipment

    Sounders, AHUs, lifts, fans and doors

  3. Example

    Flow switch showing water is flowing

    AHU shutdown in a fire

Conventional detectors are usually connected through a zone module rather than a monitor module. Monitor modules for sprinkler flow switches are covered on our flow switch control module page.

What to tell us

Panel
Make and model of the addressable panel
Devices
The list of switches and signals to monitor, per floor or zone
Contacts
Whether each device gives a normally open or normally closed contact
Location
Where each device is, so modules can be placed nearby

Supply, installation and servicing

We supply modules to match your panel, fix them near the devices they monitor, wire and address them, and program the panel so each input shows a clear location and message. Each input is tested by operating the switch or signal and checking the panel display. Under our AMC, inputs are checked during quarterly visits and the annual service.

Pump running and fault signals, tank levels and line pressure are among the parameters monitored under the Maharashtra ACMS, and FireSense IoT monitoring reports them to the owner and to us.

Engineer testing a wall-mounted fire alarm control panel, with a manual call point and a smoke detector nearby

Why choose Cease Fire

  • Since 1992

    A Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95) that designs, installs and maintains fire alarm, sprinkler and hydrant systems.

  • Proven on addressable work

    Addressable fire alarm systems at 65 Adani Electricity substations in Mumbai.

  • One team for fire systems

    We install the sprinklers, pumps and valves as well as the fire alarm, so the signals are wired and tested end to end.

Request a quote

Tell us the panel make and model and the switches or signals you need to monitor. We will confirm the modules needed and send a quote.

Frequently asked questions

What is an addressable monitor module?

It is an input device on the fire alarm loop that gives a switch or contact its own address. The panel then shows exactly which device has operated or developed a fault.

What devices can a monitor module connect?

Sprinkler flow switches, valve tamper switches, fire pump signals, gas suppression system signals, pressure switches and conventional call points. Any device with a normally open or normally closed contact can usually be monitored.

What is the difference between a monitor module and a control module?

A monitor module is an input that brings a signal into the panel. A control module is an output that switches sounders or signals other equipment, such as AHUs and lifts.

Why monitor sprinkler valve tamper switches?

A closed sprinkler valve leaves part of the building unprotected. A tamper switch on a monitor module warns the panel as soon as someone closes the valve.

Does a monitor module work with any fire alarm panel?

No, addressable modules must match the panel's make and protocol. Share the panel make and model and we will confirm a compatible module.

Can a monitor module be used for conventional smoke detectors?

Conventional detectors are usually connected through a zone module, which is designed for detector circuits. A monitor module suits single switches and contacts.

Are monitor module signals useful for ACMS?

Yes. Pump status, tank level and pressure are among the parameters the Maharashtra ACMS expects to be monitored, and our FireSense IoT panel can report them alongside the fire alarm panel.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.