Fire Protection for Warehouses and Logistics Facilities
Cease Fire & Electrical Services LLP designs, installs and maintains fire protection for warehouses, godowns and logistics parks in Mumbai, Bhiwandi, across Maharashtra and at project sites across India. We install roof and ESFR sprinklers with seismic bracing, hydrants, fire pumps and fire alarms, designed around what you store and how high you stack it, and we can monitor the pumps and sprinkler lines remotely. We delivered roof sprinklers, seismic bracing and fire alarm to FM guidelines across 4 godowns for Roquette India.
Why warehouses are hard to protect
Height and stacking
Fire climbs fast up high racks and deep stacks, and water from the roof has to reach it through the goods.
Large open areas
Without compartments, a fire can spread across the whole floor.
Changing stock
Plastics, packaging, chemicals and batteries burn very differently from paper or metal goods. A system designed for one may not control another.
Few people on site
Fires can grow unnoticed at night unless detection raises the alarm early, and a failed pump or closed valve can go unnoticed for months.
Choosing the sprinkler system
Roof sprinklers (standard)
How it worksHeads at roof level control the fire until the fire brigade arrives
When it suitsLower storage heights and lower-hazard goods
ESFR sprinklers
How it worksLarge-orifice, fast-response heads discharge heavy water to suppress the fire from the roof
When it suitsHigh-piled and rack storage, often avoiding in-rack sprinklers
In-rack sprinklers
How it worksExtra heads inside the racks
When it suitsVery high racks or goods that roof sprinklers alone cannot reach
The right choice depends on the storage height, roof height, goods stored and racking layout. We check pipe sizes and water demand with hydraulic calculations, and the design must be reviewed again whenever racking or stock changes.
The complete warehouse package
- Fire sprinkler system with seismic bracing to keep pipework in place, with alarm valves and flow switches that show which zone is operating.
- Fire hydrant system with yard hydrants around the building.
- Fire pumps and a fire pump room sized for the sprinkler and hydrant demand.
- Fire alarm with detection and zone indication.
- Extinguishers, including lithium-ion extinguishers for battery storage and forklift charging areas.
- Passive fire protection and fire doors between storage zones and offices.
- FireSense IoT monitoring of pumps, tank levels and line pressure.
Project: Roquette India, Pantnagar
For Roquette India, we installed roof sprinklers, seismic bracing and fire alarm systems in 4 godowns, to FM guidelines, between January 2023 and February 2024. Read the Roquette India case study, or see all our projects.

Monitoring pumps, tanks and sprinkler pressure
A warehouse may be empty at night, so a stopped pump, a low tank or a closed valve can go unseen. Our FireSense IoT panel reads fire pump status, water tank levels and hydrant and sprinkler line pressure, and sends the data to a cloud dashboard by SIM card, WiFi or LAN. Alerts reach your team by phone or email. Maharashtra's fire rules, amended on 12 June 2025, introduced an Automated Continuous Monitoring System (ACMS) for covered buildings, with Form A-1 from the agency and Form B-1 from the owner. See Fire IoT Monitoring System and our ACMS Form A-1 and B-1 guide.
Audits and maintenance
Warehouse fire systems fail quietly: closed valves, painted or damaged heads, stock stacked too close to sprinklers, and pumps that don't start. Our fire safety audit checks the system against how the warehouse is used now. Under a factory and warehouse AMC, most systems get quarterly checks and an annual service, with Form B every January and July.
Why choose Cease Fire
Since 1992
1,500+ fire protection projects across 25+ industries, and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ) and Fire and Life Safety Auditor. See our certifications.RF-93/ RD-95 FM experience
Warehouse sprinkler and seismic bracing work delivered to FM guidelines.
Design in-house
Hydraulic calculations with SprinkCALC and PIPENET by our MEP design team.
Book a free site survey
Share your warehouse location, area, roof and storage height, racking layout and goods stored. We will inspect the site and recommend the right system.
Frequently asked questions
What fire protection does a warehouse need?
Most warehouses need sprinklers, hydrants, fire pumps, a fire alarm and extinguishers. The type of sprinkler depends on the storage height, goods and racking, under the NBC, the Maharashtra Fire Act and any insurer requirements.
What is an ESFR sprinkler system?
ESFR stands for early suppression, fast response. ESFR heads at roof level release a large volume of water quickly to suppress fires in high-piled and rack storage.
When does a warehouse need in-rack sprinklers?
When racks are very high or the goods are hard to reach from the roof, in-rack sprinklers add protection inside the racks. ESFR systems can often avoid them, depending on the design.
Why is seismic bracing needed for sprinklers?
Bracing holds sprinkler pipes in place so they are not damaged by movement. Insurers following FM guidelines often require it.
Do I need to update my sprinkler system if I change racking or stock?
Yes. A sprinkler design is based on storage height and goods. Higher racks or more combustible goods can make the existing system inadequate, so the design should be reviewed.
How do you protect lithium-ion battery storage?
We supply lithium-ion (AVD) extinguishers for battery and charging areas, and review detection and separation from other stock as part of the design.
Can a warehouse monitor its pumps and sprinkler pressure remotely?
Yes. Our FireSense IoT panel tracks fire pump status, water tank levels and hydrant and sprinkler line pressure, and sends alerts when something is wrong. It supports the ACMS monitoring introduced by Maharashtra's rules of 12 June 2025 for covered buildings.
Do you work in Bhiwandi and outside Mumbai?
Yes. We work across Mumbai, Thane district including Bhiwandi, Maharashtra and at project sites across India, such as Roquette India in Pantnagar.
How do I book a site survey?
Call +91 9920676281, email sales@ceasefireservices.com, or use the enquiry form. The site survey is free.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281