Main Electric Fire Pump in Mumbai

Cease Fire & Electrical Services LLP supplies, installs and services the main electric fire pump for hydrant and sprinkler systems in Mumbai. The main electric pump is the duty pump in a fire pump room: it starts automatically when a hydrant is opened or a sprinkler operates, and delivers the design flow and pressure the system needs. We supply end suction, split casing, vertical and MSMO (multistage multi-outlet) designs, with UL listed and FM approved pumps available.
How the main electric pump works
In a fire pump set, the jockey pump holds the system pressure day to day. When a hydrant or sprinkler opens, pressure falls below the main pump's start setting and the fire pump control panel starts the electric pump. It then supplies full fire fighting flow to the hydrants and sprinklers. If it cannot run, for example because mains power has failed, the diesel engine fire pump takes over.
Electric fire pump designs we supply
End suction
What it isHorizontal single-stage pump with water entering at the end of the casing
Typical choice whenSmall and medium duties in most buildings
Split casing
What it isCasing opens in two halves so the impeller and bearings can be reached without disturbing the pipework
Typical choice whenLarger flows and sites where easy servicing matters
Vertical
What it isUpright pump with a small footprint
Typical choice whenPump rooms with limited floor space
MSMO (multistage multi-outlet)
What it isOne inlet with more than one outlet, each delivering a different pressure
Typical choice whenTall buildings where different zones need different pressures, which can avoid intermediate tanks or pressure-reducing valves
Flow, head and motor ratings: ask us. We size each pump to your system.
How we size the pump
A fire pump is chosen by its duty point: the flow it must deliver at a given head (pressure). We work this out from your building height, system type and hazard, using the hydraulic calculations for your hydrant and sprinkler network, then select the pump, motor and control panel to match. Share a pump schedule, BOQ or drawings and we will confirm the duty point.
Where main electric fire pumps are used

Residential towers and housing societies

Commercial buildings, offices and malls

Hospitals, hotels and schools

Factories, warehouses and industrial plants
Supply, installation and servicing
We can supply the pump on its own or as part of a complete fire pump room with the diesel and jockey pumps, control panel, valves and piping. We install, test and commission the set, and our AMC visits check the pump, motor, control panel and start sequence. Under an AMC, most systems get quarterly checks plus an annual service, and we issue Form B certificates as a licensed agency.
Under the Maharashtra ACMS rules of 12 June 2025, covered buildings must monitor pump status and pump power continuously. Our FireSense IoT panel reports main, jockey and diesel pump status and riser pressure every minute to the owner and the licensed agency. See the ACMS guide.

Why choose Cease Fire
Since 1992
A Maharashtra Fire Services Licensed Agency (MFS/
LA/ ), with 1,500+ projects.RF-93/ RD-95 UL listed and FM approved pumps available
For projects where the consultant, insurer or authority asks for them.
One team
Pump selection, pump room installation, commissioning and AMC from the same engineers.
Request a pump quote
Share your pump schedule or duty point, building type and location. We will recommend the right pump and send a quote.
Frequently asked questions
What is a main electric fire pump?
It is the duty pump in a fire fighting pump room. It starts automatically when a hydrant or sprinkler opens and supplies the full flow and pressure the system needs.
How does an electric fire pump start?
The fire pump control panel starts it when a pressure switch senses that system pressure has fallen below its set point. This happens when a hydrant is opened or a sprinkler operates.
What is an MSMO fire pump?
MSMO stands for multistage multi-outlet. It has one inlet and more than one outlet, each at a different pressure, so one pump can serve different pressure zones in a tall building.
Should I choose an end suction or split casing fire pump?
End suction pumps suit most small and medium duties. Split casing pumps suit larger flows and are easier to service in place. We recommend one after confirming your duty point.
Why do I need a diesel pump if I have an electric fire pump?
Mains power can fail during a fire. The diesel engine pump runs independently of the electricity supply, so water keeps flowing if the electric pump cannot run.
Can you supply UL listed or FM approved electric fire pumps?
Yes. UL listed and FM approved fire pumps are available. Tell us if your consultant, insurer or authority requires them and we will include the manufacturer's certificate with our quote.
How often should an electric fire pump be tested?
Your maintenance staff should run it regularly as per your system's maintenance schedule. Under our AMC, most systems also get quarterly checks and an annual service.
Can the main electric fire pump be monitored remotely under ACMS?
Yes. FireSense IoT monitoring reports pump status, pump power and riser pressure every minute, which supports the ACMS required for covered buildings in Maharashtra.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.