Fire Protection for Factories and Industrial Plants

Cease Fire & Electrical Services LLP designs, installs and maintains fire protection for factories and industrial plants in Mumbai, across Maharashtra and at project sites across India. We provide hydrant and sprinkler systems, fire alarms, foam and water spray systems, water curtain and deluge systems, gas suppression for control and electrical rooms, passive fire protection and IoT monitoring. We design to NBC, NFPA and FM guidelines as your project or insurer requires. Industrial clients include BPCL, Roquette India and Adani Electricity Mumbai.

Matching the system to the hazard

  1. Production halls and godowns

    Fast fire spread across large open areas

    Sprinklers with seismic bracing where needed, hydrants, fire alarm

  2. Flammable liquid storage and tank areas

    Liquid fires and heat affecting nearby tanks

    Foam flooding and medium or high velocity water spray, controlled by deluge valves

  3. Transformers and substations

    Oil-filled equipment fires

    Water spray systems and fire detection

  4. Openings, windows and plant boundaries

    Radiant heat from a nearby fire

    Water curtain nozzles on drencher lines

  5. Electrical panels and MCC rooms

    Electrical faults

    Electrical panel protection, tube suppression and CO2 suppression

  6. Control rooms and server rooms

    Damage from water to critical equipment

    Clean agent (Novec 1230, FM-200) or inert gas suppression

  7. High-rack storage

    Deep-seated fires in stacked goods

    See warehouses and logistics

  8. Pump house and tanks

    Loss of firefighting water

    Fire pumps (electric, diesel and jockey) with FireSense IoT monitoring

What factories in Maharashtra must comply with

  • Maharashtra Factories Rules, 1963 (Rule 71B): every factory must provide portable fire extinguishers and an adequate water supply for firefighting. Where the calculated water need is 550 litres per minute or more, power-driven trailer pumps are also required.
  • Maharashtra Fire Prevention and Life Safety Measures Act, 2006: Form A when systems are installed, and Form B from a licensed agency every January and July.
  • ACMS: the rules amended on 12 June 2025 added an Automated Continuous Monitoring System for covered buildings, with Form A-1 from the agency and Form B-1 from the owner twice a year.
  • Insurers and group standards: many plants must also meet NFPA or FM guidelines. We delivered the Roquette India godowns to FM guidelines.

Industrial projects we have delivered

  • Engineer on a scissor lift tightening the clamp of a sway brace on a red sprinkler main under a warehouse roof

    Roquette India, Pantnagar

    Roof sprinklers, seismic bracing and fire alarm, to FM guidelines, in 4 godowns (January 2023 to February 2024).

  • Engineer in a hard hat testing an open red fire alarm control panel with a handheld meter, a call point on the wall beside it

    Adani Electricity Mumbai

    Addressable fire alarm systems at 65 receiving substations (May 2024 to January 2026).

We also work for BPCL. See the Roquette India and Adani Electricity case studies, or all our projects.

See all projects and case studies

Monitoring pumps, tanks and pressure

In a plant, the fire pumps, tanks and sprinkler or drencher lines are only useful if they are ready when needed. Our FireSense IoT panel tracks fire pump status, MCC panel energy readings, water tank levels, hydrant, sprinkler and drencher line pressure, and fire alarm panel status. It sends data to a cloud server by SIM card, WiFi or LAN, and alerts your team and, where arranged, the fire department. See Fire IoT Monitoring System and the ACMS Form A-1 and B-1 guide.

Audits, training and maintenance

We plan site work with your plant team to fit around production and your site safety rules.

  • Fire safety audit by a licensed Fire and Life Safety Auditor.
  • Electrical audit and power quality audit by Class-I electrical licence holders and Level 1 thermographers, using calibrated FLIR, Testo and Fluke instruments.
  • Energy audit by BEE-certified energy auditors and managers.
  • Fire safety training for your plant team.
  • Factory AMC with quarterly checks and an annual service for most systems, and Form B on time.

Why choose Cease Fire

  • Since 1992

    1,500+ fire protection projects across 25+ industries, and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).

  • Licensed

    Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95), Fire and Life Safety Auditor, and Maharashtra Electrical Contractor Licence No. 17545. See our certifications.

  • Empanelled with BEE, NSIC, the National Safety Council and MSME.

  • Across India

    Plants in Mumbai, across Maharashtra and at project sites in other states.

Book a free site survey

Share your plant's location, what you make or store, and your current fire systems. We will inspect the site and recommend what it needs.

Frequently asked questions

What fire safety is required in a factory in Maharashtra?

The Maharashtra Factories Rules require extinguishers and an adequate water supply for firefighting, with trailer pumps above a set water demand. The Maharashtra Fire Act and the NBC set the fixed systems needed, such as hydrants, sprinklers and alarms, based on the plant's size and hazard.

Which fire protection system is used for flammable liquid storage?

Foam systems put out burning liquids by covering the surface. Water spray systems cool nearby tanks and structures. Many sites use both.

What is the difference between MVWS and HVWS?

A medium velocity water spray (MVWS) system mainly cools tanks, vessels and structures exposed to a fire. A high velocity water spray (HVWS) system is used to put out oil fires, for example on transformers.

What is a deluge valve and a water curtain used for?

A deluge valve releases water to all open nozzles of a spray or foam system when a detection signal arrives. Water curtain nozzles spray a sheet of water to protect openings, windows and boundaries from heat. We supply both and design them into water spray and drencher systems.

Do factories need a fire safety audit?

The Maharashtra Fire Act requires fire and life safety audits for certain buildings, and insurers often ask for one. We are a licensed Fire and Life Safety Auditor and also carry out electrical audits.

Can you design to FM Global guidelines?

Yes. We completed roof sprinklers, seismic bracing and fire alarm for 4 godowns at Roquette India to FM guidelines.

Can fire pumps and tank levels be monitored remotely?

Yes. Our FireSense IoT panel tracks pump status, water tank levels and hydrant, sprinkler and drencher line pressure, and sends alerts. It supports the monitoring needed under Maharashtra's ACMS rules of 12 June 2025.

Do you work on plants outside Mumbai?

Yes. We work across Maharashtra and on projects across India, such as Roquette India in Pantnagar.

How do I book a site survey for my plant?

Call +91 9920676281, email sales@ceasefireservices.com, or use the enquiry form. The site survey is free.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281