Fire Suppression for Data Centres, Server Rooms and Electrical Rooms
Cease Fire & Electrical Services LLP protects data centres, server rooms, UPS and battery rooms, electrical rooms and substations in Mumbai and across India. We design and install clean agent (Novec 1230 and FM-200), inert gas and CO2 suppression, addressable fire detection and panel-level protection, so a fire is stopped without water damage to equipment. For Adani Electricity Mumbai, we installed addressable fire alarm systems at 65 receiving substations.
Why water is not the answer in critical rooms
Sprinkler water puts out a fire but can destroy servers, switchgear and records, and take systems offline long after the fire is out. Gas suppression systems flood the room with an agent that puts out the fire and leaves no residue, so equipment can often be back in service quickly. Early detection matters just as much, because electrical fires often start slowly inside cabinets.
Choosing the suppression agent
Novec 1230 (FK-5-1-12)
How it worksClean agent that absorbs heat; safe for occupied rooms at design concentration. We supply Honeywell ECS FK-5-1-12 systems designed to NFPA 2001
Best suited toServer rooms, data halls, control rooms
FM-200 (HFC-227ea)
How it worksClean agent that absorbs heat; compact storage. We supply Honeywell FM-200 systems at 25 bar, designed to NFPA 2001
Best suited toServer rooms, telecom rooms, records rooms
Inert gas
How it worksLowers oxygen in the room to a level that stops the fire; natural gases, no residue
Best suited toLarge data halls and archives
CO2
How it worksFloods the space to smother the fire; not for normally occupied rooms
Best suited toUnoccupied electrical rooms, DG rooms, cable galleries
Tube suppression (direct and indirect) and panel protection
How it worksA heat-sensitive tube inside the cabinet bursts and releases agent at the fire's source. INTIME tube systems use FK-5-1-12
Best suited toElectrical panels, server racks, UPS cabinets
The agent, quantity and nozzle layout depend on the room volume, how airtight it is, whether people work there and the equipment inside. The room must also be sealed well enough to hold the agent long enough to work.
What a complete system includes
- Early detection: addressable smoke detection in the room, ceiling void and raised floor, with two detectors confirming before release.
- Suppression: agent cylinders, piping and nozzles sized for the room.
- Control and warning: release panel, hooters and strobes, manual release and abort switches.
- Shutdowns: signals to stop air conditioning and close dampers so the agent is held in the room.
- Room sealing: fire sealants for cable and pipe openings, and fire doors.
Electrical rooms and substations
Electrical rooms, LT and HT panels, transformer rooms and substations need detection that works in unmanned sites and reports back to a central point. For Adani Electricity Mumbai, we installed addressable fire alarm systems at 65 receiving substations between May 2024 and January 2026. Read the case study. We also carry out electrical audits with thermal imaging to find hot spots before they turn into fires.
Monitoring the building around the room
The gas system protects the room, but the building's own water-based systems still need to be ready. Our FireSense IoT panel tracks fire alarm panel status, fire pumps, water tank levels and line pressure, and alerts your team. Maharashtra's fire rules, amended on 12 June 2025, introduced an Automated Continuous Monitoring System (ACMS) for covered buildings. See Fire IoT Monitoring System.
Testing and maintenance
Gas systems need cylinder weight or pressure checks, detector tests and room integrity checks to stay ready. Under our AMC, most systems get quarterly checks and an annual service, with Form B every January and July.
Why choose Cease Fire
Since 1992
1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ), Fire and Life Safety Auditor and Maharashtra Electrical Contractor Licence No. 17545. See our certifications.RF-93/ RD-95 Brands
Honeywell clean agent systems and INTIME tube suppression. See our brands.
Fire and electrical together
Class-I electrical licence holders and Level 1 thermographers on our audit team.
Utility-scale proof
Addressable fire alarms at 65 Adani Electricity Mumbai receiving substations.
Book a free site survey
Share the room type, dimensions, equipment and whether people work in it. We will recommend the right detection and suppression and send a quote.
Frequently asked questions
Which fire suppression system is best for a server room?
Clean agent systems such as Novec 1230 or FM-200 are the usual choice. They put out the fire without water or residue and are safe for occupied rooms at design concentration. The final choice depends on room size, sealing and budget.
What is the difference between Novec 1230 and FM-200?
Both are clean agents that put out fires by absorbing heat. Novec 1230 has a much lower environmental impact, while FM-200 is widely used and compact. We recommend one based on your room and requirements.
Is CO2 suppression safe for data centres?
CO2 is not suitable for rooms where people normally work, because the concentration needed to put out a fire is dangerous to people. It suits unoccupied electrical rooms, DG rooms and cable galleries.
Why does a gas system need a sealed room?
The agent must stay in the room at the right concentration for long enough to put out the fire. Gaps around cables, pipes and doors let it escape, so openings must be sealed and the room's integrity checked.
Can a gas system go off by mistake?
Systems are designed to release only when two detectors confirm a fire, with a warning delay and an abort switch. Regular maintenance keeps false releases rare.
How do you protect electrical panels?
Tube suppression or panel protection systems place a heat-sensitive tube inside the panel that releases agent directly at the fire. Electrical audits with thermal imaging help find problems before they start a fire.
Do you work on substations and unmanned sites?
Yes. We installed addressable fire alarm systems at 65 receiving substations for Adani Electricity Mumbai.
Can the building's fire systems be monitored remotely?
Yes. Our FireSense IoT panel tracks the fire alarm panel, fire pumps, tank levels and line pressure, and sends alerts to your team. It supports the ACMS monitoring introduced by Maharashtra's rules of 12 June 2025 for covered buildings.
How do I get a quote for server room fire suppression?
Share your room dimensions and layout at sales@ceasefireservices.com, call +91 9920676281, or use the enquiry form. The site survey is free.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281