PA Hooter (Hooter cum Speaker) in Mumbai

Cease Fire & Electrical Services LLP supplies, installs and maintains the PA hooter for buildings in Mumbai, including housing societies, offices, hotels, hospitals, schools and factories. A PA hooter is a hooter cum speaker: one unit that sounds the fire alarm tone and also carries voice announcements from the public address (PA) system. It lets the building give the alarm and then tell people which floors to leave and which stairs to use, from a single device on each floor.
How a PA hooter works
The unit has two parts in one housing. The hooter is wired to the fire alarm panel and sounds automatically when a detector or call point operates. The speaker is wired to the PA amplifier and plays announcements made from the microphone or zone call station. Where the two parts are wired on separate circuits, a fault on one does not stop the other.
Hooter
Connected toFire alarm panel sounder circuit
What it doesGives the fire alarm tone automatically
Speaker
Connected toPA amplifier line
What it doesPlays live or recorded announcements
Where PA hooters are used
- Staircase lobbies and corridors of high-rise housing societies and offices
- Hotels and hospitals, where staff need to guide guests and patients floor by floor
- Schools and colleges, for evacuation instructions and daily announcements
- Factories and warehouses, where one device per bay saves wall space and cabling runs
- IS 2189:2008 defines emergency voice alarm communication as the manual or automatic means of giving voice instructions and evacuation signals to occupants in a fire emergency. Fire alarm tones still need to reach at least 65 dB(A), or 5 dB(A) above lasting background noise, wherever people may be.
What to tell us
- Fire alarm system
- Conventional or addressable, with the panel make and model
- PA system
- Existing amplifier and zone call station, or a new PA system
- Quantity
- Number of units and floors
- Mounting
- Wall or ceiling, indoor or outdoor
- Zones
- How the building should be split for announcements
Supply, installation and servicing
We supply PA hooters, wire the hooter to the fire alarm panel and the speaker to the PA amplifier, and test both parts before handover. Under our AMC, the tone and the announcements are checked on every floor during quarterly visits and the annual service.
The Maharashtra ACMS also covers the PA system, and FireSense IoT monitoring reports its status along with the fire alarm panel.

Why choose Cease Fire
Since 1992
A Maharashtra Fire Services Licensed Agency (MFS/
LA/ ) that designs, installs and maintains fire alarm and PA systems.RF-93/ RD-95 One team for both systems
We supply fire alarm and PA equipment, so the two sides of each unit are wired and tested together.
Right part first time
We confirm panel and amplifier compatibility before you order.
Request a quote
Tell us the number of floors and units, and the makes of your fire alarm panel and PA amplifier if you are adding to an existing system. We will confirm the right units and send a quote.
Frequently asked questions
What is a PA hooter?
It is a hooter cum speaker: one unit that sounds the fire alarm tone and also plays announcements from the public address system. It is usually fixed in corridors and staircase lobbies.
Why use a PA hooter instead of a separate hooter and speaker?
One unit on each floor gives both the alarm tone and voice instructions, which saves wall space and keeps the devices in one place. Staff can then tell people which floors to leave and which stairs to use.
Does a PA hooter work if the PA amplifier fails?
When the hooter part is powered by the fire alarm panel, it still sounds the alarm tone. The voice announcements need the PA amplifier to be working.
Can I connect PA hooters to my existing fire alarm and PA system?
Usually, if the hooter suits your fire alarm panel and the speaker suits your PA amplifier. Share both makes and models and we will confirm.
Where should PA hooters be installed?
In corridors, staircase lobbies and common areas on every floor, so both the tone and announcements reach everyone. Rooms behind closed doors may need their own sounder or speaker.
Is the PA system monitored under ACMS?
Yes. The Maharashtra ACMS covers the PA system along with the fire alarm panel, and our FireSense IoT panel reports both to the owner and to us.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281