Cease Fire & Electrical Services LLP supplies gas fire extinguishers in Mumbai: CO2, clean agent and other gas-filled units that put out fires without leaving powder or water behind. A gas fire extinguisher is the usual choice for electrical panels, server rooms, control rooms and equipment that powder or water would damage. We help you choose the right gas for each area, and supply, install, refill and service the units under AMC.

Types of gas fire extinguishers

  1. CO2 extinguisher

    Carbon dioxide

    Electrical panels, switch rooms, machinery, flammable liquids

  2. Clean agent extinguisher

    HFC-236fa (FE-36)

    Server rooms, electronics, offices, archives

  3. FM-200 extinguisher

    HFC-227ea

    Electronics and sensitive equipment

  4. Modular gas extinguisher

    Clean agent

    Automatic protection of small unmanned rooms

Gas-filled extinguishers are available in portable, upright and trolley versions. Ask us for the current sizes of each type.

How gas extinguishers work

Each gas works in its own way. CO2 displaces the oxygen around the fire and cools it. Clean agents such as HFC-236fa and HFC-227ea absorb heat and interrupt the chemical reaction of the fire. All of them turn to gas and disperse, leaving no residue on equipment.

Where gas extinguishers are used

  • Engineer comparing a drawing against a line of switchboard panels in an electrical room

    Electrical panels, switch rooms and meter rooms

  • Engineer checking a floor-level detector in a data centre aisle between server cabinets

    Server rooms, data centres and telecom rooms

  • Engineer checking a red fire extinguisher on the wall of a control room with an operator desk, monitors and a mimic panel

    Control rooms, laboratories and archives

  • Engineer looking up at a ceiling smoke detector on an open-plan office floor, a call point and extinguisher on the column beside him

    Offices, banks and hospitals (equipment areas)

  • Engineer fitting a red fire extinguisher to the wall of a lift machine room, beside the lift machine and its controller

    Lift machine rooms, DG rooms and UPS rooms

Supply, installation and servicing

We recommend the gas type and size for each area, mount the units near the risk with signage, and keep them ready under AMC. CO2 units are checked by weight; clean agent units by their pressure gauge. Both are refilled after use or loss of charge.

Engineer weighing a red CO2 fire extinguisher on a platform scale and noting it on a clipboard, beside a row of electrical panels with two more extinguishers on the wall

Why choose Cease Fire

  • Every gas type from one supplier

    CO2, clean agent, FM-200 and modular units.

  • Fire and electrical expertise

    Licensed fire agency and Maharashtra Electrical Contractor (Licence No. 17545).

  • Since 1992

    Supply, refilling and AMC from one licensed team.

Request a quote

Tell us the areas you want to protect and the equipment in them. We will recommend the right gas and send a quote.

Frequently asked questions

What is a gas fire extinguisher?

It is an extinguisher filled with a gas, such as CO2 or a clean agent, instead of powder, water or foam. It puts out the fire without leaving any residue.

Which gas is used in fire extinguishers?

The most common are carbon dioxide (CO2) and clean agents such as HFC-236fa (FE-36) and HFC-227ea (FM-200). Each suits slightly different risks.

Is a gas fire extinguisher safe for electrical equipment?

Yes. CO2 and clean agents do not conduct electricity and leave no residue, so they are the usual choice for panels, servers and electronics.

What is the difference between CO2 and clean agent extinguishers?

CO2 is stored at very high pressure in a heavy cylinder and works by displacing oxygen. Clean agents are stored at lower pressure with a gauge and work mainly by absorbing heat.

Do gas fire extinguishers need refilling?

Yes, after any use or loss of charge. CO2 units are checked by weighing and clean agent units by their pressure gauge, under AMC.

Can a gas extinguisher be used in a small room?

Yes, but leave the room and ventilate it after use, especially with CO2, which displaces oxygen.

Is an FM-200 extinguisher the same as an FM-200 suppression system?

No. An FM-200 extinguisher is a portable unit you operate by hand. A suppression system is fixed pipework with detection that floods the whole room automatically.