Engineer kneeling at an open electrical shaft in an apartment corridor, sealing round the cable trays at floor level with a sealant gun

Prime Smile Group, Borivali West: Fire Sealant Works for a G + 22 Tower

In a tall residential building, fire and smoke can climb through shafts, service openings and gaps around pipes and cables long before the flames do. For the Prime Smile Group's G + 22 residential tower in Borivali West, Cease Fire & Electrical Services LLP supplied and applied the passive fire protection that closes those paths: fire-rated boards, acrylic sealant and foam.

Project at a glance

Client
Prime Smile Group
Location
Borivali West, Mumbai
Building
G + 22 floors, residential
Scope
Supply and application of fire sealant works
Shaft closing
FR board with acrylic sealant, 1-hour fire rating
Gap sealing
FR foam
Fire doors
Test certificate and Form A
Order placed
November 2024
Contractor
Cease Fire & Electrical Services LLP

What we did

  • Fire and electrical shaft closing with FR board and acrylic sealant, for a 1-hour fire rating
  • Gap sealing around openings with FR foam
  • Test certificate and Form A for the fire doors

How we approached it

Passive fire protection only works when openings are sealed to the rated detail, and our crews followed the product's tested installation method. We worked floor by floor as the building progressed, closing shafts and sealing openings in sequence, and then provided the certificates the building needs for its fire inspection. See fire sealants, fire boards and fire doors.

Result

The shafts and openings were sealed to a 1-hour rating with the supporting test certificate and Form A for the fire doors, so the building has the documents to show its passive protection.

Related services and products

  • Passive fire protection
  • Fire sealants
  • Fire boards
  • Fire doors
  • Fire stop mortar

Planning a similar project?

Tell us about your building and we will survey it, recommend the systems and give you a written scope. The site survey is free.

Frequently asked questions

What is a fire sealant?

It is a material that fills gaps around pipes, cables and ducts where they pass through fire-rated walls and floors. It stops fire and smoke spreading through the opening.

What does a 1-hour fire rating mean?

It means the closure is tested to resist fire for one hour. It gives people time to leave and the fire brigade time to respond.

Why seal electrical and service shafts?

Shafts run through every floor, so they act like chimneys for fire and smoke. Closing them at each floor with rated boards and sealant breaks that path.

Do you provide test certificates?

Yes. We provide the product test certificates, and Form A for fire doors, as part of the handover documents.

Can you seal an occupied building?

Yes, in stages. We plan the work with building management so occupied areas stay protected.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281