Gate Valve (Sluice Valve) for Fire Fighting in Mumbai

Two red flanged gate valves with hand wheels

Cease Fire & Electrical Services LLP supplies the gate valve (sluice valve) for fire fighting mains in Mumbai, in flanged sizes from 50 mm to 300 mm. A gate valve lifts a wedge clear of the flow, so when fully open it gives a full-bore passage with very low pressure loss. We supply cast iron sluice valves to IS 14846 and resilient-seated ductile iron sluice valves for hydrant ring mains, pump rooms and yard pipework.

Types we supply

  1. Standard

    IS 14846

    BS 5163

  2. Sizes

    50 to 300 mm (2 to 12 inch)

    50 to 300 mm (2 to 12 inch)

  3. Body, bonnet and wedge

    Cast iron to IS 210 FG 200

    Ductile iron to BS EN 1563 (grades 450/10 and 500/7)

  4. Sealing

    Bronze seat rings (IS 318 Gr. LTB 2)

    Rubber-coated wedge, EPDM or nitrile

  5. Nuts and rings

    Bronze wedge nut and wedge ring

    Gunmetal stem nut, thrust collar and sleeve (BS 1400 LG2)

  6. Pressure rating

    PN 1.6, 2.0 and 2.5 MPa

    Ask us

  7. Hydrostatic test

    Body 2.4 MPa, seat 1.6 MPa

    Body 2.4 MPa, seat 1.6 MPa

  8. Operation

    Handwheel

    Handwheel

If your specification calls for a rising stem (OS&Y) valve, a supervisory switch or a UL listed / FM approved valve, tell us and we will confirm what we can supply.

Cast iron or resilient-seated?

Cast iron sluice valve: metal-to-metal sealing with bronze seat rings, in a simple and robust body.

Resilient-seated ductile iron: the rubber-coated wedge seals against a smooth body with no seat recess, so dirt has less place to collect. Ductile iron is also tougher than grey cast iron.

Where gate valves are used in fire systems

  • Hydrant ring mains: sectional valves, so part of the ring can be shut for repair while hydrants elsewhere stay live.
  • Pump rooms: isolation on pump suction and delivery, and on the tank outlet.
  • Yard and underground pipework: isolation on branches to buildings and yard hydrants.

Supply, installation and servicing

We supply gate valves on their own or as part of a hydrant or pump room package, and install and pressure-test them with the system. A gate valve is for full open or full close only, not for throttling. During AMC visits we operate each valve, check that it is left fully open, repack leaking glands and replace valves that have seized.

Engineer turning the hand wheel of a red gate valve on pump room pipework, with a butterfly valve, a non-return valve and a strainer along the same pipe

Why choose Cease Fire

  • Since 1992

    A Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95) with 1,500+ projects.

  • Hydrant system knowledge

    We design, install and maintain hydrant mains, so we place sectional valves where they help maintenance.

  • One supplier

    Valves, fire pumps, hydrant accessories and installation from one team.

Request a valve quote

Send your BOQ or valve list with type, sizes, pressure rating and quantity. We will confirm the specification and quote.

Frequently asked questions

Is a sluice valve the same as a gate valve?

Yes. In India "sluice valve" is the usual name for a gate valve used on water and fire mains. Both lift a gate or wedge out of the flow to open the line.

What is a gate valve used for in a fire fighting system?

It isolates a section of pipework, such as part of a hydrant ring main or a pump's suction or delivery. It should be left fully open in normal service.

What is the difference between a cast iron and a resilient-seated sluice valve?

A cast iron valve seals metal to metal with bronze seat rings. A resilient-seated valve has a rubber-coated wedge and a ductile iron body, which seals tightly and leaves no recess for dirt to collect.

Should I use a gate valve or a butterfly valve?

A gate valve gives a full-bore opening with very low pressure loss. A butterfly valve is shorter, lighter and quicker to operate. The choice depends on space, size and your specification.

What sizes and test pressures do you supply?

We supply gate valves from 50 mm to 300 mm. Both types are hydrostatically tested at 2.4 MPa on the body and 1.6 MPa on the seat.

Can a gate valve be used to control flow?

No. A gate valve should be fully open or fully closed. Running it part-open wears the wedge and seats and causes vibration.

Can you supply UL listed or FM approved gate valves?

Yes. UL listed and FM approved valves are available. Tell us what your consultant or insurer specifies, and we will share the manufacturer's certificate for the exact model with our quote.

Do you replace seized gate valves on an existing hydrant main?

Yes. We check size, rating and flange against your drawing, supply a matching valve and fit it when the section can be isolated.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.