Solenoid Valve for Fire Protection Systems in Mumbai

Cease Fire & Electrical Services LLP supplies the solenoid valve for electrically released fire protection systems in Mumbai, such as deluge, water spray, drencher and pre-action sprinkler systems. A solenoid valve is an electrically operated valve that opens or closes when its coil receives a signal, usually from the fire alarm or detection panel. In a deluge system it releases the trim pressure that holds the main valve shut, so water flows to the open nozzles.
What to tell us
- System
- Deluge, water spray, drencher, pre-action or other
- Main valve
- Make and model of the deluge or pre-action valve it will release
- Coil voltage
- For example 24 V DC, as set by the release panel
- Normal position
- Normally closed or normally open, per the valve maker's trim
- Connection
- Size and thread of the trim connection
- Approval
- UL listed, FM approved or other, as your specification requires
- Location
- Indoor, outdoor or hazardous area
We match the solenoid valve to the main valve's trim and your specification before supply.
How a solenoid valve releases a deluge valve
- In standby, the solenoid is de-energised and closed, and water pressure in the trim holds the deluge valve shut.
- Detectors or a manual release send a signal to the release panel.
- The panel energises the solenoid, which opens and vents the trim.
- The deluge valve opens and water flows to every nozzle or sprinkler in that zone.
Where solenoid valves are used
- Water spray systems (MVWS and HVWS): electric release of deluge valves protecting transformers, tanks and conveyors.
- Drencher systems: release of water curtains on openings and exposures.
- Pre-action sprinkler systems: release of the pre-action valve after detection.
- Foam flooding systems: release of the water and foam supply to the protected area.
Approvals, testing and servicing
In a deluge or pre-action system, the solenoid valve is part of a listed or approved valve assembly, so it should be the model the valve maker's trim calls for. On our projects we wire the solenoid to the release panel and test the release during commissioning. During AMC visits we check the coil and wiring, test the release from the panel, and check the manual release.
Why choose Cease Fire
Since 1992
A Maharashtra Fire Services Licensed Agency (MFS/
LA/ ) with 1,500+ projects.RF-93/ RD-95 Detection and water systems under one roof
We install fire alarm and water-based systems, so the panel, solenoid and valve are tested together.
One supplier
Solenoid valves, deluge valves, strainers and installation from one team.
Request a quote
Send your valve list or system details with the main valve model and coil voltage. We will confirm the specification and quote.
Frequently asked questions
What does a solenoid valve do in a fire protection system?
It opens or closes a line when it receives an electrical signal from the fire alarm or release panel. In deluge and pre-action systems, this is what releases the main valve.
How does a solenoid valve open a deluge valve?
In standby, water pressure in the trim holds the deluge valve shut. When the panel energises the solenoid, it vents the trim and the deluge valve opens.
Is a fire system solenoid valve normally open or normally closed?
In most deluge systems it is de-energised and closed in standby, and opens when energised. The correct type depends on the valve maker's trim.
Does the solenoid valve need UL or FM approval?
For deluge and pre-action systems it should be the listed or approved model specified for that valve. UL listed and FM approved valves are available; tell us what your consultant or insurer specifies.
How is a solenoid valve tested?
By a release test from the panel, which checks the signal, coil and valve together. We do this during commissioning and AMC visits.
What do you need to quote for a solenoid valve?
The system type, the deluge or pre-action valve it will serve, the coil voltage and the approval your specification requires.
Can you wire the solenoid valve to the fire alarm panel?
Yes. We are a licensed fire agency and electrical contractor, so we wire the solenoid to the release panel and test the release during commissioning.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281






